Transmitter |
|
|
|
|
|
Maximum output current
Maximum output voltage
Cycle |
:2, 20, 60 and 120mA(constant current)
:400V (800V peak-to-peak)
:1, 2, 4 and 8 seconds |
|
|
|
|
■ |
Receiver |
|
|
|
|
|
Number of channels
Input impedance
A/D resolution
Voltage sensitivity
Electrode array
Measurement mode
SP compensation |
:Number of channels: 4 channels (independent)
:10MΩ
:24 bits
:0.5μV
:any array
:automatic, timed and manual measurement
:automatic compensation by D/A converter |
|
|
|
|
■ |
Scanner |
|
|
Temperature logging Probe (Model-3571) |
|
|
Internal scanner
External scanner |
:Internal scanner
:Max. 256 electrodes every 64 channels, total 288 electrodes |
|
|
|
|
■ |
System control |
|
|
CPU
Storage media
Interface
Display
Display parameters
Power requirement
Power consumption
Dimensions |
:Card PC, AT compatible 586
:HDD, ZIP and FDD
:RS-232C
:10.4”, color LCD, VGA compatible
:Display parameters: injected current, 4ch potential waveform, measured values, decay curve (pole-pole array only)
:10.5V to 14V DC
:1.5A (standby), 8A (max)
:330 x 270 x 250 mm |
|
|
|
|
■ |
Applications |
|
|
|
|
|
- Long term monitoring of leakage at garbage disposal areas
- Investigation of soil contamination by waste oil
- Judgment of effectiveness of grouting
- Research and studies of liquefaction
- Investigations for dams and tunnels
- Landslide monitoring
- Ground water exploratio
|